"Product Phased Out".
Level, radar, guided.
Application: solids, liquids.
Factory precalibrated.
Incl. Setup-/diagnostic software.
:: Reliable measuring:
in dusty atmosphere,
in high + narrow silos,
in vessels + obstacles,
for changing medias.
-
Successor
-
Economically efficient basis model for all level applications in bulk solids
-
The standard sensor for highest demands in liquid level measurement
-
For all basic level applications in liquids
-
The standard sensor for highest demands for level measurement in bulk solids
-
Simple products
-
Easy to select, install and operate
Technical excellence
Simplicity
-
Standard products
-
Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
High-end products
-
Highly functional and convenient
Technical excellence
Simplicity
-
Specialized products
-
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections |
Technical excellence |
Simplicity |
Fundamental selection
Meet your basic measurement needs
|
Technical excellence
|
Simplicity
|
Lean selection
Handle your core processes easily
|
Technical excellence
|
Simplicity
|
Extended selection
Optimize your processes with innovative technologies
|
Technical excellence
|
Simplicity
|
Xpert selection
Master your most challenging applications
|
Technical excellence
|
Simplicity
|
-
Characteristic / Application
Powdered or granular solids
Suitable for measurement with heavy dust production
-
Supply / Communication
2-wire 16-36V, DC
4-wire 10,5-32V, DC
4-wire 90-250V, 50/60Hz
-
Ambient temperature
-40 °C ... +80 °C
(-40°F ... 176 °F)
-
Process temperature
-40 °C ... +150 °C
(-40°F ... 302°F)
-
Process pressure / max. overpressure limit
Vacuum...40bar
(Vaccum...580psi)
-
-
Process connection
3/4" + 1-1/2" G+NPT
Flange >=DN40
-
Blocking distance
Top: 200mm (7.87")
Bottom: 250mm (9.87") (Rope probe)
-
Sensor length
Rod probe: 4m (13ft)
Rope probe: 35m (115ft)
-
Max. measurement distance
-
Communication
4 ... 20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
-
Certificates / Approvals
ATEX
FM
CSA
TIIS
WGH
SIL
NACE
EN10204-3.1
-
Options
Separate electronics, separate display
-
-
-
Characteristic / Application
Characteristic / Application
-
Interface measurement
Clean interfaces liquid / liquid
Simultaneous measurment of interface and overall level
-
Supply / Communication
2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)
-
-
Ambient temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
-
Process temperature
-40 °C ... 150 °C
(-40 °F ... 302 °F)
-
Process pressure / max. overpressure limit
Vacuum ... 40 bar
(Vacuum ... 580 psi)
-
-
Process connection
G + NPT 3/4" and 1 1/2", DN40 ... DN150
-
Sensor length
Rod: 4m (178")
Coax: 4m (178")
Rope: 35m (1378")
-
-
Max. measurement distance
Max. measurement distance
-
Communication
4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
-
Certificates / Approvals
ATEX
FM
CSA
TIIS
WHG/ Overfill prevention
SIL
NACE
GL Marine
EN10204-3.1
IECEx
-
-
Most downloaded
-
Levelflex M FMP40, FMP45
English version - 02/2008
|
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1
Zone 0/1, Zone 1
Protection: Ex ia IIC T6...T1
|
EN
|
|
More
|
01/02/2008
|
|
|
|
01/06/2004
|
|
|
|
Language:
|
English
|
Version:
|
01/02/2008
|
File size:
|
846.1 KB
|
File name:
|
XA164FA3_0208.pdf
|
-
Levelflex M FMP40
Technical Information
English version - 10/2012
|
Guided Level Radar
Continuous Level Transmitter for
'- Level Measurement in Bulk Solids and Liquids
'- Interface Measurement in Liquids
|
EN
|
|
More
|
15/10/2012
|
|
|
|
13/09/2012
|
|
|
|
22/12/2010
|
|
|
|
17/04/2009
|
|
|
|
20/02/2008
|
|
|
|
Language:
|
English
|
Version:
|
15/10/2012
|
File size:
|
4.7 MB
|
File name:
|
TI00358FEN_1512.pdf
|
123 documents
-
Levelflex M FMP40
Technical Information
Guided Level Radar
Continuous Level Transmitter for
'- Level Measurement in Bulk Solids and Liquids
'- Interface Measurement in Liquids
|
EN
|
|
Select other language
|
15/10/2012
|
|
|
|
13/09/2012
|
|
|
|
22/12/2010
|
|
|
|
17/04/2009
|
|
|
|
20/02/2008
|
|
|
|
Language:
|
English
|
Version:
|
15/10/2012
|
File size:
|
4.7 MB
|
File name:
|
TI00358FEN_1512.pdf
|
-
Levelflex / Levelflex M
Zentrierscheibe / Centering disk (PFA)
Mounting Instructions
Accessory
|
EN
|
|
Select other language
|
29/09/2017
|
|
|
|
27/02/2014
|
|
|
|
25/04/2012
|
|
|
|
08/02/2011
|
|
|
|
24/09/2010
|
|
|
|
Language:
|
English
|
Version:
|
29/09/2017
|
File size:
|
82.6 KB
|
File name:
|
BA00378FA2_1717.pdf
|
-
Levelflex M FMP40
Interface measurement
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for interface measurement in liquids
|
EN
|
|
Select other language
|
14/01/2010
|
|
|
|
17/04/2009
|
|
|
|
17/03/2008
|
|
|
|
Language:
|
English
|
Version:
|
14/01/2010
|
File size:
|
3.9 MB
|
File name:
|
BA00363FEN_1310.pdf
|
-
|
EN
|
|
Select other language
|
27/02/2014
|
|
|
|
24/09/2010
|
|
|
|
03/12/2008
|
|
|
|
02/04/2008
|
|
|
|
Language:
|
English
|
Version:
|
27/02/2014
|
File size:
|
99.3 KB
|
File name:
|
BA00377FA2_1414.pdf
|
-
Levelflex M FMP40
HART
Operating Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in bulk solids and
liquids.
|
EN
|
|
Select other language
|
21/01/2010
|
|
|
|
17/04/2009
|
|
|
|
10/11/2006
|
|
|
|
31/05/2006
|
|
|
|
16/01/2006
|
|
|
|
Language:
|
English
|
Version:
|
21/01/2010
|
File size:
|
5.9 MB
|
File name:
|
BA00242FEN_1310.pdf
|
-
Levelflex M FMP40
PROFIBUS PA
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in bulk solids and
liquids.
|
EN
|
|
Select other language
|
03/02/2010
|
|
|
|
17/04/2009
|
|
|
|
10/11/2006
|
|
|
|
31/05/2006
|
|
|
|
01/01/2006
|
|
|
|
Language:
|
English
|
Version:
|
03/02/2010
|
File size:
|
6.6 MB
|
File name:
|
BA00243FEN_1310.pdf
|
-
Levelflex M FMP40, FMP41C, FMP45
Measurement
Guided Level Radar for Interface Measurement with HART
|
EN
|
|
Select other language
|
01/02/2008
|
|
|
|
Language:
|
English
|
Version:
|
01/02/2008
|
File size:
|
1.3 MB
|
File name:
|
BA366FEN_0108.pdf
|
-
Levelflex M FMP40
FOUNDATION Fieldbus
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in bulk solids and
liquids.
|
EN
|
|
Select other language
|
11/11/2010
|
|
|
|
28/08/2009
|
|
|
|
17/04/2009
|
|
|
|
10/11/2006
|
|
|
|
31/05/2006
|
|
|
|
Language:
|
English
|
Version:
|
11/11/2010
|
File size:
|
6.9 MB
|
File name:
|
BA00244FEN_1310.pdf
|
-
Levelflex M FMP40, FMP41C, FMP43, FMP45
HART, PA, FF
Description of Instrument Functions
Smart Transmitter for continuous
level measurement in liquids
|
EN
|
|
Select other language
|
01/07/2007
|
|
|
|
07/06/2006
|
|
|
|
25/01/2006
|
|
|
|
12/07/2004
|
|
|
|
23/02/2004
|
|
|
|
Language:
|
English
|
Version:
|
01/07/2007
|
File size:
|
1.5 MB
|
File name:
|
BA245FEN_0707.pdf
|
-
Levelflex M FMP40
FOUNDATION Fieldbus
Brief
Operating Instructions
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in bulk solids and
liquids.
|
EN
|
|
Select other language
|
11/11/2010
|
|
|
|
10/08/2009
|
|
|
|
Language:
|
English
|
Version:
|
11/11/2010
|
File size:
|
1.5 MB
|
File name:
|
KA01040FEN_1310.pdf
|
Search spare parts by number in drawing
42 spare parts & accessories
42 spare parts
42 accessories
-
-
Set of screws housing F12/T12/F23
Drawing number
Order code
12
535720-9020
-
Cover F12/T12 Alu, coated, gasket
Drawing number
Order code
20
517391-0011
-
Cover F12/T12 Alu, window, gasket
Drawing number
Order code
20
52005936
-
Cover T3/T12 Alu, coated, gasket
Drawing number
Order code
25
518710-0020
-
Cover terminal compartment F12/F23
Drawing number
Order code
11
52006026
-
Cover terminal compartment F12/F23,FHX40
Drawing number
Order code
11
52019062
-
Terminal module 4-pole, HART, 2-wire
Drawing number
Order code
35
52006197
-
Terminal module 4-pole, PA, FF
Drawing number
Order code
35
52012156
-
Terminal mod. Ex d, 4-pol., 2wr,HART,T12
Drawing number
Order code
35
52013302
-
Terminal mod. Ex d, 2-pol.,2wr,PA/FF,T12
Drawing number
Order code
35
52013303
-
Terminal mod. 4-pol.,EEx ia,HART,T12,OVP
Drawing number
Order code
35
52018949
-
Terminal mod. 2-p.,EEx ia,PA/FF,T12,OVP
Drawing number
Order code
35
52018950
-
Drawing number
Order code
11
52005643
-
Power supply 10.5-32VDC (housing F12)
Drawing number
Order code
35
52013304
-
Power supply 90-250VAC (F12), Ex only
Drawing number
Order code
35
52013305
-
Power supply CSA, 10.5-32VDC (housg F12)
Drawing number
Order code
35
52015585
-
Power supply CSA, 90-250VAC (housg F12)
Drawing number
Order code
35
52015586
-
Drawing number
Order code
40
52026443
-
Sealing ring G1-1/2, 48x55 FA, 5 pcs.
-
Sealing ring G3/4, 27x32, FA, 5 pcs.
-
Adaption kit housing F12, 2-wire, FHX40
-
Adaption kit housing F12, 4-wire, FHX40
-
-
Nordlock washer DIN25201-A4, M10, 5 pcs.
Drawing number
Order code
59
71023427
-
-
-
-
-
Modification name plate, non Ex
-
Threaded pin M10x1, AlloyC22
-
HF-test cable 6GHz + resistor
-
Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60
-
-
-
Protective cover for housing T12/F12, SS
-
-
Mounting bracket FHX40 1" / 2" pipe
-
Isolation tie down of the 4mm rope probe
-
Isolation tie down of the 6mm rope probe
-
Centering star PEEK 48-95mm/1.89-3.74in
-
Centering star PFA 37mm/16mm
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .