Non-contact installation: any Within installation: -40°C ... +70°C (-40°F ... +158°F) With high temperature adapter: up to +450°C (+842°F)
Process pressure / max. overpressure limit
Non-contact installation: any Within installation: 0.5 bar ... 6.8 bar (7.2 psi ... 99 psi) abs. With high pressure adapter: up to +21 bar (+305 psi) abs.
The Soliwave microwave barrier uses a non-contact procedure for detection of point levels and bulk flow (flow / no flow, trend). The device is also suitable for detecting and counting objects, detection of deposits as well as monitoring of filling processes and material transfer points. It can be installed in containers, conduits, hoppers, filling stations, shafts, filters or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside.
Non-contact (wear- and maintenance-free) limit detection (min/max) and flow monitoring (flow/no flow, trend) for bulk solids.
Detecting, counting and positioning of objects
Detection and analysis of deposits and contamination in filters
Monitoring of filling processes
Monitoring of material transfer points
For high temperature applications up to 450°C (+842°F)
For high pressure applications up to 20bar (+290psi)
International explosion protection certificates
Benefits
Simple assembly with R 1½, 1½ NPT thread or G 1½ (with lock nut)
Mechanically robust construction ensures cost savings over the whole life cycle of the product: No wear and tear, process-wetted ceramic sensor diaphragm (optional), long serviceable life, maintenance free
Mechanically compatible to FQR50/FDR50 and FQR56/FDR56 microwave barrier, existing process connections can be used; likewise, accessories such as adapter flanges, installation brackets and sight glasses can be used again
Increased safety of the point level monitoring by optional integrated bulk flow monitoring
Measuring principle almost independent of the process properties
Can also be used in difficult applications, where other measurement methods fail
Easy operation via the Nivotester FTR525 with graphical display saves time and reduces costs
Torishima designs and builds large cooling water systems for customers in the Middle East, relying on Endress+Hauser instrumentation for the quality and performance of the products.
Global crop protection and seed technology company Nufarm reduces measurement uncertainty to less than 1% with new-generation 80 GHz radar level sensors
Portland Bunkers UK Ltd operates a state-of-the-art fuel storage terminal on the south coast. Due to the risk of pollution from high volumes of oil, advanced monitoring is required at all times.
Kemira, a global chemicals company, needs accurate monitoring of level and temperature for polymer manufacturing. They use instrumentation with Bluetooth for safe and easy access to process data.
Transceiver Non-contact point level detection and flow monitoring Detecting, counting and positioning of objects Monitoring of material transfer points Detection and analysis of deposits and contamination Installation: Non-contact installation (tranmission window) or front-flush installation (contact)
Specialities
With optional integrated bulk flow monitoring Parallel mode with up to 5 channels Detection range limit: max. 100 m Detection range flow: max. 10 m, depending on bulk solids
Supply / Communication
Via process transmitter with control unit Nivotester FTR525
Ambient temperature
-40 °C...+70 °C (-40 °F...+158 °F)
Process temperature
Non-contact installation: any Within installation: -40°C ... +70°C (-40°F ... +158°F) With high temperature adapter: up to +450°C (+842°F)
Process pressure / max. overpressure limit
Non-contact installation: any Within installation: 0.5 bar ... 6.8 bar (7.2 psi ... 99 psi) abs. With high pressure adapter: up to +21 bar (+305 psi) abs.
Min. density of medium
Solid weight: > 10 g/l
Main wetted parts
Non-contact installation: no wetted parts Within installation: 316Ti, PTFE or Ceramic
Process connection
Threads: 1-1/2" R, 1-1/2" G, 1-1/2" NPT
Communication
Via process transmitter with control unit Nivotester FTR525
Certificates / Approvals
ATEX, CSA C/US, IEC Ex
Design approvals
EN10204-3.1
Options
Sight glass High temperature adapter High pressure adapter Installation bracket FAR50, FAR51, FAR52, FAR53, FAR54, FAR55
Non-contact installation: any Within installation: -40°C...+70°C (-40°F...+158°F) With high temperature adapter: up to +450°C (+842°F)
Process pressure / max. overpressure limit
Non-contact installation: any Within installation: 0.5 bar...6.8 bar (7.2 psi ... 99 psi) abs. With high pressure adapter: up to +21 bar (+305 psi) abs.
Non-contact installation: any Within installation: -40°C...+70°C (-40°F...+158°F) With high temperature adapter: up to +450°C (+842°F)
Process pressure / max. overpressure limit
Non-contact installation: any Within installation: 0.5 bar...6.8 bar (7.2 psi ... 99 psi) abs. With high pressure adapter: up to +21 bar (+305 psi) abs.